logotype
  • HOME
  • INSTITUTE
  • CONFERENCE PROGRAM
  • ABOUT THE EVENT
    • COMMITTEE
  • SPEAKERS
  • GALLERY 2025
  • LOCATION
  • CONTACT
  • ARCHIVE
    • TID 2024
      • BOOK OF ABSTRACTS
      • CONFERENCE PROGRAM
      • SPEAKERS
      • PROGRAM COMMITTEE
      • ORGANIZATIONAL COMMITTEE
      • GALLERY
    • TID 2023
      • BOOK OF ABSTRACTS
      • PROGRAM
      • SPEAKERS
      • GALLERY
  • Srpski jezik
  • English
  • Srpski jezik
  • English
  • HOME
  • INSTITUTE
  • CONFERENCE PROGRAM
  • ABOUT THE EVENT
    • COMMITTEE
  • SPEAKERS
  • GALLERY 2025
  • LOCATION
  • CONTACT
  • ARCHIVE
    • TID 2024
      • BOOK OF ABSTRACTS
      • CONFERENCE PROGRAM
      • SPEAKERS
      • PROGRAM COMMITTEE
      • ORGANIZATIONAL COMMITTEE
      • GALLERY
    • TID 2023
      • BOOK OF ABSTRACTS
      • PROGRAM
      • SPEAKERS
      • GALLERY
  • Srpski jezik
  • English
logotype
logotype
  • HOME
  • INSTITUTE
  • CONFERENCE PROGRAM
  • ABOUT THE EVENT
    • COMMITTEE
  • SPEAKERS
  • GALLERY 2025
  • LOCATION
  • CONTACT
  • ARCHIVE
    • TID 2024
      • BOOK OF ABSTRACTS
      • CONFERENCE PROGRAM
      • SPEAKERS
      • PROGRAM COMMITTEE
      • ORGANIZATIONAL COMMITTEE
      • GALLERY
    • TID 2023
      • BOOK OF ABSTRACTS
      • PROGRAM
      • SPEAKERS
      • GALLERY
  • Srpski jezik
  • English
Dr. Valentina Vasović
HomeTeamDr. Valentina Vasović
Nikola Tesla Institute

Dr. Valentina Vasović

3PINT and related innovative technologies as permanent solution to mitigate corrosive sulphur in power transformers / Aging Tests of Alternative Insulating Liquids

ABSTRACT: 3PINT and related innovative technologies as permanent solution to mitigate corrosive sulphur in power transformers

Focus of 3PINT project is to upgrade readiness level of the innovative technology for the removal of corrosive sulphur, PCB and aging product from transformer oils. Technology itself includes chemical conversion process to refine transformer oils in eco-frendly manner. Used technology is environmentally closed with no toxic emissions and waste released into environment. In addition, innovative solution for corroded silver-plated contacts cleaning, effectively removes silver sulphide deposits from OLTC contacts, ensuring long-term reliability and complete power transformer corrosive sulphur mitigation.

Keywords: 3PINT, innovative technology, environmentally closed technology, power transformer, complete corrosive sulphur mitigation

Abstract: Aging Tests of Alternative Insulating Liquids

Using alternative insulation liquids as a replacement of mineral oil took place since decades. Until now there is no regulation in the standards to identify the degradation of solid or liquid insulation under the application of alternative liquids. Most of investigations rely on the guidance known and used for mineral oil, which leads mostly to confusion and are misleading. Determination of aging and end of life for transformers filled with mineral oil is based on huge amount of information and experience gathered since oil transformers were built. The limits of key properties and DGA analysis are well defined for reconditioning, reclaiming and replacement of mineral oil as well as for fault detection in transformers. Efforts of research community were focused to extract these rules and modify them to fit to alternative liquids, however, until now there is no real success in this area. In this study, comparative laboratory aging tests of two natural esters of the same base were performed. Tests were conducted at 180 °C in stainless steel vessels with two different types of paper and four different metallic components in defined ratios corresponding to real power transformers. After several aging periods up to 28 days was finished, the key properties of insulating liquids were measured, such as: gasses dissolved in the oil, acidity, breakdown voltage, water content, interfacial tension, viscosity, antioxidant content, as well as degree of polymerization of the paper and water content in the paper. The aging results provided valuable insights into the differences in aging and gas emission patterns of the tested liquids, which varied depending on the type of paper used and the antioxidants present in the liquids. Additionally, the study demonstrated the interrelationship of liquid properties at various stages of paper degradation. The findings highlighted the importance of performing compatibility tests between insulating liquids and other materials intended for use before their application in power transformers.

Keywords: Aging Test, Compatibility, Lifetime, Natural Ester, Power Transformer

Biography of the presenter

Valentina Vasovic is a senior associate in Laboratory for insulating oil and paper testing of the Nikola Tesla Institute of Electrical Engineering, Belgrade, Serbia. She earned Ph.D. degree in chemical engineering from the Faculty of Technology and Metallurgy, University of Belgrade, Serbia. Her main fields of expertise are insulating oil and paper analyses, power transformers condition assessment, water distribution phenomena in the oil/cellulose insulation, thermal parameters and aging process of insulation system of power transformers, risk assessment related to power transformer insulation ageing and applicability of alternative liquids in power transformers. She is a member of currently ongoing CIGRE WG D1.76 and CIGRE JWG D1/A2.80, and member of Serbian National Committee CIGRE SC A2 as well as Technical Committees N010 and N015 of the Serbian Institute for Standardization.